{"product_id":"manx-laser-ml-ad3-3-stage-air-drying-system","title":"Manx Laser ML-AD3 – 3 Stage Air Drying System","description":"\u003cp\u003e\u003cstrong\u003eThree-stage compressed-air filtration, pressure regulation and desiccant drying in one compact unit.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eManx Laser ML-AD3 3 Stage Air Drying System\u003c\/strong\u003e combines a particulate filter\/regulator, a fine coalescing filter and a replaceable desiccant dryer. It is designed to help reduce particles, liquid moisture and oil aerosols, then remove residual water vapour from the compressed-air supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePrice: £195.00 + VAT.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eHow the three stages work\u003c\/h2\u003e\u003ch3\u003eStage 1 — Filter and pressure regulator\u003c\/h3\u003e\u003cp\u003eA \u003cstrong\u003e5-micron filter element\u003c\/strong\u003e captures particles and separates condensed water. The pressure-adjustment knob lifts to unlock, turns to adjust and pushes down to lock the setting. This stage has an automatic condensate drain.\u003c\/p\u003e\u003ch3\u003eStage 2 — Coalescing filter\u003c\/h3\u003e\u003cp\u003eA \u003cstrong\u003e0.01-micron element\u003c\/strong\u003e, as specified in the supplier's product description, provides fine filtration for liquid droplets, oil aerosols and contaminants. The indicator on top changes from green to red when the filter requires attention. This stage has a manual drain.\u003c\/p\u003e\u003ch3\u003eStage 3 — Desiccant dryer\u003c\/h3\u003e\u003cp\u003eReplaceable desiccant beads adsorb residual water vapour. The supplied indicating beads change from blue towards pink as they become saturated, providing a visible reminder to replace the desiccant.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-stage filtration and drying with an integrated pressure regulator.\u003c\/li\u003e\n\u003cli\u003eLockable pressure-adjustment knob and pressure gauge.\u003c\/li\u003e\n\u003cli\u003eAutomatic first-stage drainage and manual second-stage drainage.\u003c\/li\u003e\n\u003cli\u003eVisual filter-service and desiccant indicators.\u003c\/li\u003e\n\u003cli\u003eReplaceable filter elements and desiccant.\u003c\/li\u003e\n\u003cli\u003eAluminium construction with mounting brackets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd\u003eML-AD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir inlet and outlet\u003c\/th\u003e\n\u003ctd\u003e½-inch BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGauge connection\u003c\/th\u003e\n\u003ctd\u003e¼-inch BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStage 1 element\u003c\/th\u003e\n\u003ctd\u003e5 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStage 2 element\u003c\/th\u003e\n\u003ctd\u003e0.01 microns — supplier specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStage 3\u003c\/th\u003e\n\u003ctd\u003eReplaceable indicating desiccant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBody material\u003c\/th\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall dimensions\u003c\/th\u003e\n\u003ctd\u003eApproximately 238.8 mm wide × 279.4 mm high × 114.3 mm deep, as shown in the supplier's drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eListed operating temperature\u003c\/th\u003e\n\u003ctd\u003e5–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eInstallation and maintenance\u003c\/h2\u003e\u003cp\u003eInstall upright and follow the airflow-direction arrow on the unit. Set the outlet pressure to suit the connected equipment, check the drains regularly and replace filter elements and desiccant when indicated. Isolate the air supply and fully depressurise the unit before removing bowls or changing consumables.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Confirm the required airflow, pressure and air-quality specification for your equipment before use. A maximum airflow rating and guaranteed pressure dew point have not been provided, so suitability for a particular laser or process must be checked rather than assumed.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eSpecification note: the supplier's literature gives differing pressure figures of 1.6 and 1.65 MPa. Always follow the pressure rating marked on the supplied unit and the limits of the connected equipment. Filtration percentages shown in the product graphic are supplier claims, not independently verified performance ratings.\u003c\/small\u003e\u003c\/p\u003e","brand":"Manx Laser","offers":[{"title":"Default Title","offer_id":55786429219157,"sku":"ML-AD3","price":195.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1012\/8893\/5765\/files\/manx-laser-ml-ad3-studio.png?v=1794599460","url":"https:\/\/manxlaser.com\/products\/manx-laser-ml-ad3-3-stage-air-drying-system","provider":"manxlaser","version":"1.0","type":"link"}